Couplers - Ancillary Hardware

Qualification

Our Couplers are qualified to all major satellite bus electrical, mechanical and environmental interfaces.

Test Couplers

  • Test Coupler ICD – WR229
  • Test Coupler- WR137
  • Test Coupler- WR112
  • Test Coupler- WR75

Combiner Couplers

  • Combiner Couplers – WR 51
  • Combiner Couplers – WR 75

Directional Couplers

  • Directional Coupler- WR75
  • Directional Coupler- WR62
  • Directional Coupler- WR51
180 Watt X-Band BPF with Coupler and Isolator

WR 112 Test Coupler

Compact High Directivity coupler

Compact High Directivity coupler

WR 51 Combiner Coupler

WR 51 Combiner Coupler

Examples

The Coupler Products illustrated below are a few examples of the many types of delivered units.

Xguide coupler

Crossguide Coupler X guide coupler

WR 229 Test Coupler

WR 229 Test Coupler

WR 137 Test Coupler

WR 137 Test Coupler

WR 75 Combiner Coupler

WR 75 Combiner Coupler

WR 62 Coupler

WR 62 Coupler

Product Specifications

Couplers

WR 229 Test Coupler

Parameter Units Performance
Frequency Range GHz 3.4 to 4.2
Insertion Loss dB 0.1
Coupling dB 33
Coupling Variation dB 1.5
Directivity dB 20
VSWR Main/Coupled dB 23/20
RF Leakage dBc -90
Temp Range Deg C -30 to 120
Mass Grams 290

WR 137 Test Coupler

Parameter Units Performance
Frequency Range GHz 5.8 to 6.8
Insertion Loss dB 0.1
Coupling dB 33
Coupling Variation dB 1.5
Directivity dB 20
VSWR Main/Coupled dB 23/20
RF Leakage dBc -90
Temp Range Deg C -30 to 120
Mass Grams 158

WR 112 Test Coupler

Parameter Units Performance
Frequency Range GHz 7.9 to 8.3
Insertion Loss dB 0.15
Coupling dB 30
Coupling Variation dB 2
Directivity dB 20
VSWR Main/Coupled dB 23/20
RF Leakage dBc -90
Temp Range Deg C -30 to 120
Mass Grams 140

WR 75 Combiner Coupler

Parameter Units Performance
Frequency Range GHz 10.7 to 12.7
Insertion Loss dB 1.25
Coupling dB 6.5
Coupling Variation dB 0.5
Isolation dB 25
VSWR Main/Coupled dB 23/20
RF Leakage dBc -90
Temp Range Deg C -30 to 120
Mass Grams 78

WR 62 Coupler

Parameter Units Performance
Frequency Range GHz 17.3 to 17.8
Insertion Loss dB 1.25
Coupling dB 4.5
Coupling Variation dB 0.3
Isolation dB 25
VSWR Main/Coupled dB 23/20
RF Leakage dBc -90
Temp Range Deg C -30 to 120
Mass Grams 153

WR 51 Combiner Coupler

Parameter Units Performance
Frequency Range GHz 18.5 to 19.5
Insertion Loss dB 1.5
Coupling dB 6.5
Coupling Variation dB 0.3
Isolation dB 25
VSWR Main/Coupled dB 23/20
RF Leakage dBc -90
Temp Range Deg C -30 to 120
Mass Grams 140