Phase Locked DROs
External Reference
2 - 4 GHz
2.0 - 2.8 GHz
Phase Locked DROs - External Reference
Phase Locked DROs - External Reference
Parameters | Units |
Specifications | ||||||
Model Number |
LO-020-E4B |
LO-021-E4B |
LO-022-E4B |
LO-023-E4B |
LO-024-E4B |
LO-026-E4B |
LO-027-E4B |
|
Frequency |
GHz |
1.955-2.097 |
2.098-2.205 |
2.206-2.318 |
2.319-2.437 |
2.438-2.562 |
2.563-2.693 |
2.694-2.831 |
RF power (5) |
dBm |
12-15 |
12-15 |
12-15 |
12-15 |
12-15 |
12-15 |
12-15 |
Reference frequency (1) |
MHz |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
Reference power (2) |
dBm |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
Phase noise |
(1 Hz BW) |
|||||||
@100 kHz |
dBc/Hz |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
@100 kHz |
dBc/Hz |
-131 |
-130 |
-130 |
-129 |
-129 |
-129 |
-128 |
@1 MHz |
dBc/Hz |
-141 |
-141 |
-141 |
-141 |
-141 |
-141 |
-141 |
Mechanical tuning (6) |
MHz |
>+/-1.637 |
>+/-1.721 |
>+/-1.810 |
>+/-1.902 |
>+/-2.000 |
>+/-2.102 |
>+/-2.210 |
Size |
inches |
2" x 1.883" x 0.652" |
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652" |
2" x 1.883" x 0.652" |
Outline PDF |
2.8 - 4.0 GHz
Phase Locked DROs - External Reference
Phase Locked DROs - External Reference
Parameters | Units |
Specifications | ||||||
Model Number |
LO-029-E4B |
LO-030-E4B |
LO-032-E4B |
LO-033-E4B |
LO-035-E4B |
LO-037-E4B |
LO-039-E4B |
|
Frequency |
GHz |
2.832-2.976 |
2.977-3.129 |
3.130-3.290 |
3.291-3.458 |
3.459-3.636 |
3.637-3.822 |
3.823-4.018 |
RF power (5) |
dBm |
12-15 |
12-15 |
12-15 |
12-15 |
12-15 |
12-15 |
12-15 |
Reference frequency (1) |
MHz |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
Reference power (2) |
dBm |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
Phase noise |
(1 Hz BW) |
|||||||
@100 kHz |
dBc/Hz |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
@100 kHz |
dBc/Hz |
-128 |
-127 |
-127 |
-126 |
-126 |
-126 |
-125 |
@1 MHz |
dBc/Hz |
-141 |
-141 |
-141 |
-141 |
-141 |
-141 |
-141 |
Mechanical tuning (6) |
MHz |
>+/-2.323 |
>+/-2.442 |
>+/-2.568 |
>+/-2.700 |
>+/-2.838 |
>+/-2.984 |
>+/-3.136 |
Size |
inches |
2" x 1.883" x 0.652" |
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652" |
2" x 1.883" x 0.652" |
Outline PDF |
Other Parameters Common to Lucix 2.0 - 4.0 GHz GHz PLDRO-ER
Harmonics |
Spurious |
Supply |
Temperature |
Stability Over Temperature (p-p) |
Lock Alarm |
|||
dBc |
dBc |
Voltage V(3) |
Current mA |
Operating °C |
Storage °C |
Frequency ppm (4) |
Power dB (5) |
|
-25 |
-70 |
12-16 |
325 |
-40 to +70 |
-55 to +85 |
2 |
TTL Low |
- The [output frequency/(reference frequency)] must be an integer. The integer value N determines the phase noise at 100kHz offsets.
- The reference power is required to fall within a 6 dB window over the specified power range. Higher operating power yields better phase noise performance.
- Loop bandwidth setting based on reference noise characteristics, typically 10 kHz to 200 kHz.
- Total power variation over entire operating temperature range.
- Higher output power is available. Please contact the factory for more information.
- Not applicable to hermetically sealed Rugged Ultra Reliable DRO products.
- Rugged Ultra Reliable DRO products measure 2.350 x 2.000 x 0.700.
DROs
Free Running DROs
Phase Locked DROs
External Reference
Phase Locked DROs
Internal Reference