Free Running DROs
26.5 - 44 GHz
26.5 - 33.9 GHz
Free Running DROs
Free Running DROs
Parameters | Units |
Specifications | ||||
Model Number |
LO-271-FD |
LO-285-FD |
LO-299-FD |
LO-315-FD |
LO-330-FD |
|
Frequency |
GHz |
26.5-27.84 |
27.84-29.25 |
29.25-30.73 |
30.73-32.29 |
32.29-33.92 |
RF power |
dBm |
6-9 |
6-9 |
6-9 |
6-9 |
5-8 |
Frequency pushing |
kHz |
10 |
10 |
10 |
10 |
10 |
Load pulling (2) |
MHz |
5.44 |
5.7 |
6 |
6.3 |
6.62 |
Phase noise |
(1 Hz BW) |
|||||
@10 kHz |
dBc/Hz |
-83 |
-83 |
-82 |
-82 |
-82 |
@100 kHz |
dBc/Hz |
-108 |
-108 |
-107 |
-107 |
-107 |
@1 MHz |
dBc/Hz |
-133 |
-133 |
-132 |
-132 |
-132 |
Frequency stability (4) |
MHz |
2.72 |
2.85 |
3 |
3.15 |
3.31 |
Mechanical tuning |
MHz |
>+/-21.8 |
>+/-22.8 |
>+/-24.0 |
>+/-25.1 |
>+/-26.4 |
Electrical tuning, min (1) |
MHz |
9.3 |
9.7 |
10.2 |
10.7 |
11.2 |
Tune voltage range (1) |
V |
0.6 to 7.4 |
0.6 to 7.4 |
0.6 to 7.4 |
0.6 to 7.4 |
0.6 to 7.4 |
Tune voltage center (1) |
V |
4 |
4 |
4 |
4 |
4 |
Size |
inches |
1.608" x .993" x 0.612" |
1.608" x .993" x 0.612"
|
1.608" x .993" x 0.612"
|
1.608" x .993" x 0.612"
|
0.610" x .1.230" x 0.495"
|
Outline PDF |
33.9 - 44 GHz
Free Running DROs
Free Running DROs
Parameters | Units |
Specifications | ||||
Model Number |
LO-347-FD |
LO-365-FD |
LO-383-FD |
LO-403-FD |
LO-423-FD |
|
Frequency |
GHz |
33.92-35.64 |
35.64-37.44 |
37.44-39.34 |
39.34-41.33 |
41.33-43.42 |
RF power |
dBm |
5-8 |
5-8 |
5-8 |
4-7 |
4-7 |
Frequency pushing |
kHz |
10 |
10 |
10 |
10 |
10 |
Load pulling (2) |
MHz |
6.96 |
7.3 |
7.68 |
8.04 |
8.48 |
Phase noise |
(1 Hz BW) |
|||||
@10 kHz |
dBc/Hz |
-81 |
-81 |
-80 |
-80 |
-80 |
@100 kHz |
dBc/Hz |
-106 |
-106 |
-105 |
-105 |
-105 |
@1 MHz |
dBc/Hz |
-131 |
-131 |
-130 |
-130 |
-130 |
Frequency stability (4) |
MHz |
3.48 |
3.65 |
3.84 |
4.02 |
4.24 |
Mechanical tuning |
MHz |
>+/-27.8 |
>+/-29.2 |
>+/-30.8 |
>+/-32.2 |
>+/-34.0 |
Electrical tuning, min (1) |
MHz |
11.8 |
12.4 |
13.1 |
13.7 |
14.5 |
Tune voltage range (1) |
V |
0.6 to 7.4 |
0.6 to 7.4 |
0.6 to 7.4 |
0.6 to 7.4 |
0.6 to 7.4 |
Tune voltage center (1) |
V |
4 |
4 |
4 |
4 |
4 |
Size |
inches |
0.610" x 1.230" x 0.495" |
0.610" x 1.230" x 0.495"
|
0.610" x 1.230" x 0.495"
|
0.610" x 1.230" x 0.495""
|
0.610" x 1.230" x 0.495"
|
Outline PDF |
Other Parameters Common to Lucix 26.5 - 44 GHz FRDRO
Harmonics |
Spurious |
Supply |
Temperature |
Stability Over Temperature (p-p) |
Aging |
|||
dBc |
dBc |
Voltage V(3) |
Current mA |
Operating °C |
Storage °C |
Frequency ppm (4) |
Power dB (5) |
ppm/year |
-25 |
-95 |
5-16 |
135 |
-40 to +70 |
-55 to +85 |
100 |
3 |
+/- 1 |
- Varactor tuning is included in every unit.
- Maximum frequency variation for 360 phase change in a 1.5:1 load.
- Recommended input voltage.
- Unit equipped with on board regulator.
- Total frequency variation over entire operating temperature range.
- Total power variation over entire operating temperature range.
DROs
Free Running DROs
Phase Locked DROs
External Reference
Phase Locked DROs
Internal Reference