Free Running DROs
26.5 - 44 GHz

26.5 - 33.9 GHz
Free Running DROs
Parameters
Units
Specifications
Model Number
LO-271-FD
LO-285-FD
LO-299-FD
LO-315-FD
LO-330-FD
Frequency
GHz
26.5-27.84
27.84-29.25
29.25-30.73
30.73-32.29
32.29-33.92
RF power
dBm
6-9
6-9
6-9
6-9
5-8
Frequency pushing
kHz
10
10
10
10
10
Load pulling (2)
MHz
5.44
5.7
6
6.3
6.62
Phase noise
(1 Hz BW)
@10 kHz
dBc/Hz
-83
-83
-82
-82
-82
@100 kHz
dBc/Hz
-108
-108
-107
-107
-107
@1 MHz
dBc/Hz
-133
-133
-132
-132
-132
Frequency stability (4)
MHz
2.72
2.85
3
3.15
3.31
Mechanical tuning
MHz
>+/-21.8
>+/-22.8
>+/-24.0
>+/-25.1
>+/-26.4
Electrical tuning, min (1)
MHz
9.3
9.7
10.2
10.7
11.2
Tune voltage range (1)
V
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
Tune voltage center (1)
V
4
4
4
4
4
Size
inches
1.608" x .993" x 0.612"
1.608" x .993" x 0.612"
1.608" x .993" x 0.612"
1.608" x .993" x 0.612"
0.610" x .1.230" x 0.495"
Outline PDF
 
33.9 - 44 GHz
Free Running DROs
Parameters
Units
Specifications
Model Number
LO-347-FD
LO-365-FD
LO-383-FD
LO-403-FD
LO-423-FD
Frequency
GHz
33.92-35.64
35.64-37.44
37.44-39.34
39.34-41.33
41.33-43.42
RF power
dBm
5-8
5-8
5-8
4-7
4-7
Frequency pushing
kHz
10
10
10
10
10
Load pulling (2)
MHz
6.96
7.3
7.68
8.04
8.48
Phase noise
(1 Hz BW)
@10 kHz
dBc/Hz
-81
-81
-80
-80
-80
@100 kHz
dBc/Hz
-106
-106
-105
-105
-105
@1 MHz
dBc/Hz
-131
-131
-130
-130
-130
Frequency stability (4)
MHz
3.48
3.65
3.84
4.02
4.24
Mechanical tuning
MHz
>+/-27.8
>+/-29.2
>+/-30.8
>+/-32.2
>+/-34.0
Electrical tuning, min (1)
MHz
11.8
12.4
13.1
13.7
14.5
Tune voltage range (1)
V
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
Tune voltage center (1)
V
4
4
4
4
4
Size
inches
0.610" x 1.230" x 0.495"
0.610" x 1.230" x 0.495"
0.610" x 1.230" x 0.495"
0.610" x 1.230" x 0.495""
0.610" x 1.230" x 0.495"
Outline PDF
 

Other Parameters Common to Lucix 26.5 - 44 GHz FRDRO
Harmonics
Spurious
Supply
Temperature
Stability Over Temperature (p-p)
Aging
dBc
dBc
Voltage V(3)
Current mA
Operating °C
Storage °C
Frequency ppm (4)
Power dB (5)
ppm/year
-25
-95
5-16
135
-40 to +70
-55 to +85
100
3
+/- 1
  1. Varactor tuning is included in every unit.
  2. Maximum frequency variation for 360 phase change in a 1.5:1 load.
  3. Recommended input voltage.
  4. Unit equipped with on board regulator.
  5. Total frequency variation over entire operating temperature range.
  6. Total power variation over entire operating temperature range.

DROs