Phase Locked DROs
External Reference
26.5 - 44 GHz
26.5 - 33.9 GHz
Phase Locked DROs - External Reference
Phase Locked DROs - External Reference
Parameters | Units |
Specifications | ||||
Model Number |
LO-271-ED |
LO-285-ED |
LO-299-ED |
LO-315-ED |
LO-330-ED |
|
Frequency |
GHz |
26.501-27.840 |
27.841-29.250 |
29.251-30.730 |
30.731-32.290 |
32.291-33.920 |
RF power (5) |
dBm |
7-10 |
7-10 |
7-10 |
7-10 |
6-9 |
Reference frequency (1) |
MHz |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
Reference power (2) |
dBm |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
Phase noise |
(1 Hz BW) |
|||||
@100 kHz |
dBc/Hz |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
@100 kHz |
dBc/Hz |
-108 |
-108 |
-107 |
-107 |
-107 |
@1 MHz |
dBc/Hz |
-133 |
-133 |
-132 |
-132 |
-132 |
Mechanical tuning (6) |
MHz |
>+/-21.8 |
>+/-22.8 |
>+/-24.0 |
>+/-25.1 |
>+/-26.4 |
Size |
inches |
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652"
|
2" x 1.5" x 0.50"
|
Outline PDF |
33.9 - 44 GHz
Phase Locked DROs - External Reference
Phase Locked DROs - External Reference
Parameters | Units |
Specifications | ||||
Model Number |
LO-347-ED |
LO-365-ED |
LO-383-ED |
LO-403-ED |
LO-423-ED |
|
Frequency |
GHz |
33.921-35.640 |
35.641-37.440 |
37.441-39.340 |
39.341-41.330 |
41.331-43.420 |
RF power (5) |
dBm |
6-9 |
6-9 |
6-9 |
6-9 |
6-9 |
Reference frequency (1) |
MHz |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
Reference power (2) |
dBm |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
Phase noise |
(1 Hz BW) |
|||||
@100 kHz |
dBc/Hz |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
@100 kHz |
dBc/Hz |
-106 |
-106 |
-105 |
-105 |
-105 |
@1 MHz |
dBc/Hz |
-131 |
-131 |
-130 |
-130 |
-130 |
Mechanical tuning (6) |
MHz |
>+/-27.8 |
>+/-29.2 |
>+/-30.8 |
>+/-32.2 |
>+/-34.0 |
Size |
inches |
2" x 1.5" x 0.50"
|
2" x 1.5" x 0.50"
|
2" x 1.5" x 0.50"
|
2" x 1.5" x 0.50"
|
2" x 1.5" x 0.50"
|
Outline PDF |
Other Parameters Common to Lucix 26.5- 44 GHz GHz PLDRO-ER
Harmonics |
Spurious |
Supply |
Temperature |
Stability Over Temperature (p-p) |
Lock Alarm |
|||
dBc |
dBc |
Voltage V(3) |
Current mA |
Operating °C |
Storage °C |
Frequency ppm (4) |
Power dB (5) |
|
-25 |
-80 |
12-16 |
200 |
-40 to +70 |
-55 to +85 |
3 |
TTL Low |
- The [output frequency/(reference frequency)] must be an integer. The integer value N determines the phase noise at 100kHz offsets.
- The reference power is required to fall within a 6 dB window over the specified power range. Higher operating power yields better phase noise performance.
- Loop bandwidth setting based on reference noise characteristics, typically 10 kHz to 200 kHz.
- Total power variation over entire operating temperature range.
- Higher output power is available. Please contact the factory for more information.
- Not applicable to hermetically sealed Rugged Ultra Reliable DRO products.
- Rugged Ultra Reliable DRO products measure 2.350 x 2.000 x 0.700.
DROs
Free Running DROs
Phase Locked DROs
External Reference
Phase Locked DROs
Internal Reference