Phase Locked DROs
External Reference
1 - 2 GHz
1.0 - 1.4 GHz
Phase Locked DROs - External Reference
Phase Locked DROs - External Reference
Parameters | Units |
Specifications | ||||||
Model Number |
LO-0102-E8B |
LO-0107-E8B |
LO-0113-E8B |
LO-0118-E8B |
LO-0125-E8B |
LO-0131-E8B |
LO-0138-E8B |
|
Frequency |
GHz |
.998-1.049 |
1.050-1.102 |
1.103-1.159 |
1.160-1.218 |
1.219-1.281 |
1.282-1.347 |
1.348-1.416 |
RF power (5) |
dBm |
12-15 |
12-15 |
12-15 |
12-15 |
12-15 |
12-15 |
12-15 |
Reference frequency (1) |
MHz |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
Reference power (2) |
dBm |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
Phase noise |
(1 Hz BW) |
|||||||
@100 kHz |
dBc/Hz |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
@100 kHz |
dBc/Hz |
-137 |
-136 |
-136 |
-135 |
-135 |
-135 |
-134 |
@1 MHz |
dBc/Hz |
-141 |
-141 |
-141 |
-141 |
-141 |
-141 |
-141 |
Mechanical tuning (6) |
MHz |
>+/-.819 |
>+/-.861 |
>+/-.905 |
>+/-.951 |
>+/-1.000 |
>+/-1.052 |
>+/-1.106 |
Size |
inches |
2" x 1.883" x 0.652" |
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652" |
2" x 1.883" x 0.652" |
Outline PDF |
1.4 - 2.0 GHz
Phase Locked DROs - External Reference
Phase Locked DROs - External Reference
Parameters | Units |
Specifications | ||||||
Model Number |
LO-0145-E8B |
LO-0152-E8B |
LO-0160-E8B |
LO-0168-E8B |
LO-0177-E8B |
LO-0186-E8B |
LO-0196-E8B |
|
Frequency |
GHz |
1.417-1.488 |
1.489-1.565 |
1.566-1.645 |
1.646-1.729 |
1.730-1.818 |
1.819-1.911 |
1.912-2.009 |
RF power (5) |
dBm |
12-15 |
12-15 |
12-15 |
12-15 |
12-15 |
12-15 |
12-15 |
Reference frequency (1) |
MHz |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
50 to 500 |
Reference power (2) |
dBm |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
-3 to +13 |
Phase noise |
(1 Hz BW) |
|||||||
@100 kHz |
dBc/Hz |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
20*log(N)+3 |
@100 kHz |
dBc/Hz |
-134 |
-133 |
-133 |
-132 |
-132 |
-132 |
-131 |
@1 MHz |
dBc/Hz |
-141 |
-141 |
-141 |
-141 |
-141 |
-141 |
-141 |
Mechanical tuning (6) |
MHz |
>+/-1.162 |
>+/-1.222 |
>+/-1.284 |
>+/-1.350 |
>+/-1.419 |
>+/-1.492 |
>+/-1.568 |
Size |
inches |
2" x 1.883" x 0.652" |
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652"
|
2" x 1.883" x 0.652" |
2" x 1.883" x 0.652" |
Outline PDF |
Other Parameters Common to Lucix 1.0- 2.0 GHz GHz PLDRO-ER
Harmonics |
Spurious |
Supply |
Temperature |
Stability Over Temperature (p-p) |
Lock Alarm |
|||
dBc |
dBc |
Voltage V(3) |
Current mA |
Operating °C |
Storage °C |
Frequency ppm (4) |
Power dB (5) |
|
-25 |
-70 |
12-16 |
325 |
-40 to +70 |
-55 to +85 |
2 |
TTL Low |
- The [output frequency/(reference frequency)] must be an integer. The integer value N determines the phase noise at 100kHz offsets.
- The reference power is required to fall within a 6 dB window over the specified power range. Higher operating power yields better phase noise performance.
- Loop bandwidth setting based on reference noise characteristics, typically 10 kHz to 200 kHz.
- Total power variation over entire operating temperature range.
- Higher output power is available. Please contact the factory for more information.
- Not applicable to hermetically sealed Rugged Ultra Reliable DRO products.
- Rugged Ultra Reliable DRO products measure 2.350 x 2.000 x 0.700.
DROs
Free Running DROs
Phase Locked DROs
External Reference
Phase Locked DROs
Internal Reference