Free Running DROs
16 - 26.5 GHz

16.0 - 20.6 GHz
Free Running DROs
Parameters
Units
Specifications
Model Number
LO-164-FC
LO-173-FC
LO-182-FC
LO-191-FC
LO-201-FC
Frequency
GHz
16.071-16.900
16.901-17.760
17.761-18.670
18.671-19.630
19.631-20.640
RF power
dBm
9-12
9-12
8-11
8-11
8-11
Frequency pushing
kHz
10
10
10
10
10
Load pulling (2)
MHz
3.3
3.46
3.64
3.82
4.02
Phase noise
(1 Hz BW)
@10 kHz
dBc/Hz
-88
-87
-87
-86
-86
@100 kHz
dBc/Hz
-113
-112
-112
-111
-111
@1 MHz
dBc/Hz
-138
-137
-137
-136
-136
Frequency stability (4)
MHz
1.65
1.73
1.82
1.91
2.01
Mechanical tuning
MHz
>+/-13.2
>+/-13.8
>+/-14.6
>+/-15.2
>+/-16.0
Electrical tuning, min (1)
MHz
5.6
5.9
6.2
6.5
6.8
Tune voltage range (1)
V
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
Tune voltage center (1)
V
4
4
4
4
4
Size
inches
0.640" X 0.720" X 0.499"
0.640" X 0.720" X 0.499"
0.640" X 0.720" X 0.499"
0.640" X 0.720" X 0.499"
0.640" X 0.720" X 0.499"
Outline PDF
 
20.6 - 26.5 GHz
Free Running DROs
Parameters
Units
Specifications
Model Number
LO-211-FC
LO-222-FC
LO-233-FC
LO-245-FC
LO-258-FC
Frequency
GHz
20.641-21.700
21.701-22.810
22.811-23.980
23.981-25.210
25.211-26.500
RF power
dBm
8-11
7-10
7-10
7-10
7-10
Frequency pushing
kHz
10
10
10
10
10
Load pulling (2)
MHz
4.24
4.46
4.68
4.92
5.18
Phase noise
(1 Hz BW)
@10 kHz
dBc/Hz
-85
-85
-85
-84
-84
@100 kHz
dBc/Hz
-110
-110
-110
-109
-109
@1 MHz
dBc/Hz
-135
-135
-135
-134
-134
Frequency stability (4)
MHz
0.212
2.23
2.34
2.46
2.59
Mechanical tuning
MHz
>+/-17.0
>+/-17.8
>+/-18.8
>+/-19.6
>+/-20.8
Electrical tuning, min (1)
MHz
7.2
7.6
8.0
8.3
8.8
Tune voltage range (1)
V
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
0.6 to 7.4
Tune voltage center (1)
V
4
4
4
4
4
Size
inches
0.640" X 0.720" X 0.499"
0.640" X 0.720" X 0.499"
0.640" X 0.720" X 0.499"
0.640" X 0.720" X 0.499"
0.640" X 0.720" X 0.499"
Outline PDF
 

Other Parameters Common to Lucix 16.0 - 26.5 GHz FRDRO
Harmonics
Spurious
Supply
Temperature
Stability Over Temperature (p-p)
Aging
dBc
dBc
Voltage V(3)
Current mA
Operating °C
Storage °C
Frequency ppm (4)
Power dB (5)
ppm/year
-25
-95
5-16
55
-40 to +70
-55 to +85
100
2
+/- 1
  1. Varactor tuning is included in every unit.
  2. Maximum frequency variation for 360 phase change in a 1.5:1 load.
  3. Recommended input voltage.
  4. Unit equipped with on board regulator.
  5. Total frequency variation over entire operating temperature range.
  6. Total power variation over entire operating temperature range.

DROs