Phase Locked DROs
External Reference
4 - 8 GHz

4.0 - 5.7 GHz
Phase Locked DROs - External Reference
Parameters
Units
Specifications
Model Number
LO-040-E2B
LO-043-E2B
LO-045-E2B
LO-047-E2B
LO-049-E2B
LO-052-E2B
LO-055-E2B
Frequency
GHz
3.991-4.195
4.196-4.410
4.411-4.636
4.637-4.874
4.875-5.124
5.125-5.386
5.387-5.662
RF power (5)
dBm
12-15
12-15
12-15
12-15
12-15
12-15
12-15
Reference frequency (1)
MHz
50 to 500
50 to 500
50 to 500
50 to 500
50 to 500
50 to 500
50 to 500
Reference power (2)
dBm
-3 to +13
-3 to +13
-3 to +13
-3 to +13
-3 to +13
-3 to +13
-3 to +13
Phase noise
(1 Hz BW)
@100 kHz
dBc/Hz
20*log(N)+3
20*log(N)+3
20*log(N)+3
20*log(N)+3
20*log(N)+3
20*log(N)+3
20*log(N)+3
@100 kHz
dBc/Hz
-125
-124
-124
-123
-123
-123
-122
@1 MHz
dBc/Hz
-141
-141
-141
-141
-141
-141
-141
Mechanical tuning (6)
MHz
>+/-3.274
>+/-3.442
>+/-3.619
>+/-3.804
>+/-4.000
>+/-4.204
>+/-4.420
Size
inches
2" x 1.883" x 0.652"
2" x 1.883" x 0.652"
2" x 1.883" x 0.652"
2" x 1.883" x 0.652"
2" x 1.883" x 0.652"
2" x 1.883" x 0.652"
2" x 1.883" x 0.652"
Outline PDF
 
5.7 - 8.0 GHz
Phase Locked DROs - External Reference
Parameters
Units
Specifications
Model Number
LO-058-E2B
LO-061-E2B
LO-064-E2B
LO-067-E2B
LO-070-E2B
LO-074-E2B
LO-078-E2B
Frequency
GHz
5.663-5.953
5.954-6.258
6.259-6.579
6.580-6.916
6.917-7.271
7.272-7.644
7.645-8.036
RF power (5)
dBm
12-15
12-15
12-15
12-15
12-15
12-15
12-15
Reference frequency (1)
MHz
50 to 500
50 to 500
50 to 500
50 to 500
50 to 500
50 to 500
50 to 500
Reference power (2)
dBm
-3 to +13
-3 to +13
-3 to +13
-3 to +13
-3 to +13
-3 to +13
-3 to +13
Phase noise
(1 Hz BW)
@100 kHz
dBc/Hz
20*log(N)+3
20*log(N)+3
20*log(N)+3
20*log(N)+3
20*log(N)+3
20*log(N)+3
20*log(N)+3
@100 kHz
dBc/Hz
-122
-121
-121
-120
-120
-120
-119
@1 MHz
dBc/Hz
-141
-141
-141
-141
-141
-141
-141
Mechanical tuning (6)
MHz
>+/-4.646
>+/-4.885
>+/-5.135
>+/-5.398
>+/-5.675
>+/-5.966
>+/-6.272
Size
inches
2" x 1.883" x 0.652"
2" x 1.883" x 0.652"
2" x 1.883" x 0.652"
2" x 1.883" x 0.652"
2" x 1.883" x 0.652"
2" x 1.883" x 0.652"
2" x 1.883" x 0.652"
Outline PDF
 


Other Parameters Common to Lucix 4.0 - 8.0 GHz GHz PLDRO-ER
Harmonics
Spurious
Supply
Temperature
Stability Over Temperature (p-p)
Lock Alarm
dBc
dBc
Voltage V(3)
Current mA
Operating °C
Storage °C
Frequency ppm (4)
Power dB (5)
-25
-70
12-16
325
-40 to +70
-55 to +85
2
TTL Low
  1. The [output frequency/(reference frequency)] must be an integer. The integer value N determines the phase noise at 100kHz offsets.
  2. The reference power is required to fall within a 6 dB window over the specified power range. Higher operating power yields better phase noise performance.
  3. Loop bandwidth setting based on reference noise characteristics, typically 10 kHz to 200 kHz.
  4. Total power variation over entire operating temperature range.
  5. Higher output power is available. Please contact the factory for more information.
  6. Not applicable to hermetically sealed Rugged Ultra Reliable DRO products.
  7. Rugged Ultra Reliable DRO products measure 2.350 x 2.000 x 0.700.

DROs

CONTACT SALES FOR PRODUCT SPECIFICATIONS